Cat® CG Series

Cat® CG – ATS for general purpose applications

The CG Series – Contactor-type, Open Transition (CG) and Delayed Transition (CGD) ATS for general purpose applications offers functionality for critical emergency power applications in commercial and light industrial applications, with an enhanced feature set and LCD HMI interface.The CG provides a durable mechanism that is tested up to 6,000 cycles. Electrical system parameters are set via the HMI and pre-configuration file upload is available via USB or Bluetooth connection.

Product Images

Product Videos

Virtual Product Tour (VPT)

Specifications

NameTypeValueUnit Value (Imperial)Unit NameUnit Value (Metric)Unit Name (Metric)
Rating Rangetext30 - 3000 A
Transfer TypetextOpen Transition (CG), Delayed Transition (CGD)
Switch TypetextContactor

View All Specifications (9)

Documents & Spec Sheets

CG - ATS (General Purpose)

Download

Rating Guide

Download

Features & Benefits

Product Features
  • Voltage and frequency sensing of both sources and load
  • USB port to upload/download settings
  • Available Bluetooth connection and enhanced communication capabilities
  • Password protection LCD HMI
  • Integrated help button and menu
  • Automatic Configuration Function
Control Panel
  • TruOne L3 - CG LCD HMI to set electrical system parameters with file upload via USB or Bluetooth connection.
Functions
  • Provision of transfer & re-transfer control signals
  • Provision of engine/generator start and shutdown signals
  • Permit user programming of set points
  • Display real time and historical information
  • Permit system testing
  • Store all parameters in nonvolatile memory
Standards
  • UL 1008, NFPA 70, 99, 101 and 110
  • NEMA ICS 10
  • cUL

Complete Specifications

Technical Summary

NameTypeValueUnit Value (Imperial)Unit NameUnit Value (Metric)Unit Name (Metric)
Rating Rangetext30 - 3000 A
Transfer TypetextOpen Transition (CG), Delayed Transition (CGD)
Switch TypetextContactor
Product nodestext30, 60, 100, 125, 160, 200, 260, 400, 600, 800, 1000, 1200, 1600, 2000, 2600, 3000A
Rated Voltage and Frequencytext200-480VAC, 50/60 Hz
Phase systemtextSingle and Three (three phase only >600A)
Number of polestext2, 3 and 4 (3 & 4 pole only >600A)
Neutral configurationtextOptional Solid or Switched neutral
Product typetextOpen transition (I-II), Delayed Transition (I-O-II)

Standard Equipment

Control

  • LCD + keys
  • Voltage and frequency settings: Pick up and Drop out
  • Time Delay Settings: Override momentary, Transfer, Generator stop, Center-OFF, Pre-transfer, Post-transfer, Elevator Pre-signal, Elevator Post-signal, and Load shead
  • Source failure detections: No Voltage, Under/Over Voltage, Phase missing, Voltage unbalance, Invalid frequency, and Incorrect phase sequence

Additional Features

  • LED indications for ATS, S1 and S2 status
  • Open transition - Standard digital inputs/outputs (1/1)
  • Delayed transition - Standard digital inputs/outputs (2/1)
  • Programmable digital inputs/outputs
  • Auto config (voltage, frequency, phase system)
  • Source priority (Source 1/2, No priority)
  • Manual re-transfer
  • In-phase monitor (synchro check)
  • Genset exercising: on-load, off-load
  • Load shedding
  • Real time clock
  • Event log

Optional Equipment

Accessories

  • Auxiliary contacts for position indication
  • Additional digital input/output contacts (adding up to 6 each)
  • 12-24 VDC aux supply module for controller
  • Communication modules

Connectivity Capability

  • Modbus RTU (RS-485)
  • Modbus/TCP
  • Profibus DP
  • ProfiNet Yes
  • DeviceNet
  • Ethernet IP

Attachments