3412C | 750 ekW

3412C | 750 ekW 60 Hz Generator Set

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

Product Images

Product Videos

Virtual Product Tour (VPT)

Specifications

NameTypeValueUnit Value (Imperial)Unit NameUnit Value (Metric)Unit Name (Metric)
Maximum Ratingtext800 ekW
Standby Ratingtext750 ekW
Minimum Ratingtext635 ekW

View All Specifications (22)

Documents & Spec Sheets

Electric Power Ratings Guide

Download

3412, 60 Hz, 635-800 ekW, Low Fuel Consumption Spec Sheet

Download

Features & Benefits

Cat Generator Set Package
  • Cat generator set packages have been fully prototype tested
  • Accepts 100% block load in one step and meets NFPA 110 loading requirements
  • Conform to ISO 8528-5 steady state and transient response requirements
Cat Diesel Engine
  • Reliable, rugged, durable design
  • Field-proven in thousands of applications worldwide
  • Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight
SR500 Alternator
  • Superior motor starting capability minimizes need for oversizing alternator
  • Designed to match performance and output characteristics of Cat diesel engines
  • Robust Class H insulation
EMCP 4 Control Panel
  • User-friendly interface and navigation
  • Scalable system to meet a wide range of installation requirement
  • Expansion modules and site-specific programming for specific customer requirements
Cooling System
  • Designed to operate in standard ambient temperatures up to 50°C (122°F)
  • Contact your Cat Dealer for specific ambient and altitude capabilities
Certifications
One Safe Source
  • Components used in the generator set are selected at the design stage to provide optimum package performance
  • The generator set is fully assembled at a Caterpillar facility following our quality guidelines
  • Each generator set package is tested before leaving the Caterpillar facility
  • Cat product support, including dealer service, parts and warranty covers the entire Cat power system
World Wide Product Support
  • Cat dealers have over 1,800 dealer branch stores operating in 200 countries
  • Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements

Complete Specifications

Generator Set Specifications

NameTypeValueUnit Value (Imperial)Unit NameUnit Value (Metric)Unit Name (Metric)
Maximum Ratingtext800 ekW
Standby Ratingtext750 ekW
Minimum Ratingtext635 ekW
Prime Power Ratingtext680 ekW
Emissions/Fuel StrategytextLow BSFC
Voltagetext220 to 480 Volts
Frequencytext60 Hz
Speedtext1800 rpm
Duty CycletextStandby, Prime
Engine Modeltext3412C TA, V-12, 4-Stroke Water-Cooled Diesel
Boremeasurement5.4in137.2mm
Strokemeasurement6in152.4mm
Displacementmeasurement1648.86in³27.02l
Compression Ratiotext13:00:01
AspirationtextTA
Fuel SystemtextPump and Lines
Governor TypetextADEM™ A5
Length - Maximummeasurement162.4in4125mm
Width - Maximummeasurement78.3in1989mm
Height - Maximummeasurement75in1906mm
Dry Weight - Genset (minimum)measurement5761lb12700kg
Dry Weight - Genset (maximum)measurement13275lb6021kg

Standard Equipment

Air Inlet System

  • Air cleaner, single element canister type
  • Single element canister type

Control Panel

  • Failure to start (overcrank)
  • Emergency stop
  • EMCP 4.2B
  • Speed adjust
  • Remote Serial annunciator
  • Communications:
  • Controls:
  • Digital Indicator for:
  • Engine cycle crank
  • Voltage adjust
  • Compatible with the following optional modules:
  • Digital I/O module
  • Overspeed
  • Low coolant level
  • Serial annunciator module data link
  • Volts (L-L & L-N)
  • Emergency stop pushbutton
  • Generator temperature monitoring module
  • Frequency (Hz)
  • Run/auto/ stop/control
  • DC volts
  • High coolant temperature
  • Oil pressure (psi, kPa or bar)
  • Customer data link (Modbus RTU)
  • RPM
  • coolant temperature
  • Amps (per phase & average)
  • Operating hours.
  • Local annunciator
  • Low oil pressure
  • Power factor (per phase & average)
  • Remote CAN annunciator
  • Low coolant temperature
  • Accessory module data link
  • Warning shutdowns:

Cooling System

  • Coolant drain line with valve
  • Caterpillar extended life coolant
  • Fan and belt guards
  • Radiator with guard (sized for 50 degrees C)

Exhaust System

  • Stainless steel exhaust flex with ANSI style outlet flange

Fuel System

  • Primary and Secondary fuel filters
  • Water separator
  • Fuel priming pump

Generator and Attachments

  • 3 Phase sensing
  • Class H insulation
  • Busbar termination
  • 12 Leads
  • SR4B self excited
  • Reactive droop
  • Class F temperature rise
  • VR6B voltage regulator
  • 2:1 Volts/Hz

Governing System

  • Cat electronic governor

Lube System

  • Oil drain line with valve
  • Oil filter
  • Lubricating oil

Mounting System

  • Base, formed steel with linear vibration isolators between base and engine-generator

Starting / Charging System

  • 24 Volt starting motor
  • Battery with rack, cables
  • 45 Amp Charging alternator
  • Fuel shutoff solenoid

General

  • Paint - Caterpillar yellow except rails and radiators gloss black

Optional Equipment

Air Inlet System

  • Air cleaner - single element
  • Air cleaner - Dual element
  • Air cleaner - Heavy element

Certificates

  • EU Certification

Circuit breakers

  • 3 Pole Circuit breakers with shunt trip
  • Power terminal strip
  • 4 Pole Circuit breakerswith shunt trip

Control Panel

  • Temperature monitoring package
  • EMCP 4.3, EMCP 4.4
  • Vandal proof panel door
  • Common alarm/shutdown relay
  • Generator running VFC
  • Earth leakage Ground fault relay

Cooling System

  • Radiator removal
  • Jacket water heater
  • Radiator duct flange

Exhaust System

  • Through wall installation kit
  • Manifold and turbocharger guards
  • Muffler 35 dBA attenuation
  • Muffler 10 dBA attenuation
  • Elbow mounting kit

Fuel System

  • Automatic fuel transfer system
  • Manual fuel transfer pump

Generator and Attachments

  • Oversize and premium generators
  • Permanent magnet excitation (PMG)
  • Anti-condensation heater
  • Internal excitation (IE)

Governing System

  • Electronic load share

Lube System

  • Manual sump pump

Mounting System

  • Fuel tank base (1200 Ltr)

Special Tests / Reports

  • PGS Test report @ 1.0 power factor
  • Factory witness test
  • PGS Test report @ 0.8 power factor

Starting / Charging system

  • Battery chargers
  • Oversize battery set
  • Heavy duty starting system
  • Battery disconnect switch
  • Battery removal

Enclosures

  • DC lighting package
  • Weather protective enclosure (WP)
  • Sound attenuated enclosure (SA)

Attachments