3412C | 900 kVA

3412C | 900 kVA 50Hz Generator Set

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

Product Images

Product Videos

Virtual Product Tour (VPT)

Specifications

NameTypeValueUnit Value (Imperial)Unit NameUnit Value (Metric)Unit Name (Metric)
Maximum Ratingtext900 kVA
Standby Ratingtext900 kVA
Minimum Ratingtext810 kVA

View All Specifications (23)

Documents & Spec Sheets

Electric Power Ratings Guide

Download

3412, 50 Hz, 680-900 kVA Low Fuel Consumption Spec Sheet

Download

Features & Benefits

Cat Generator Set Package
  • Cat generator set packages have been fully prototype tested
  • Accepts 100% block load in one step and meets NFPA 110 loading requirements
  • Conform to ISO 8528-5 steady state and transient response requirements
Cat Diesel Engine
  • Reliable, rugged, durable design
  • Field-proven in thousands of applications worldwide
  • Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight
SR500 Alternator
  • Superior motor starting capability minimizes need for oversizing alternator
  • Designed to match performance and output characteristics of Cat diesel engines
  • Robust Class H insulation
EMCP 4 Control Panel
  • User-friendly interface and navigation
  • Scalable system to meet a wide range of installation requirement
  • Expansion modules and site-specific programming for specific customer requirements
Cooling System
  • Designed to operate in standard ambient temperatures up to 50°C (122°F)
  • Contact your Cat Dealer for specific ambient and altitude capabilities
Certifications
  • EU Declaration of Conformity
  • EU Declaration of Incorporation
  • Eurasian Conformity (EAC)
One Safe Source
  • Components used in the generator set are selected based on seamless design integration to provide the optimum performance
  • The generator set is fully assembled at a Caterpillar facility following our quality guidelines
  • Each generator set package is tested before leaving the Caterpillar facility
  • Cat product support, including dealer service, parts and warranty covers the entire Cat power system
World Wide Product Support
  • Cat dealers have over 1,800 dealer branch stores operating in 200 countries
  • Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements

Complete Specifications

Generator Set Specifications

NameTypeValueUnit Value (Imperial)Unit NameUnit Value (Metric)Unit Name (Metric)
Maximum Ratingtext900 kVA
Standby Ratingtext900 kVA
Minimum Ratingtext810 kVA
Prime Power Ratingtext810 kVA
Emissions/Fuel StrategytextLow BSFC
Voltagetext380 to 415 Volts
Frequencytext50 Hz
Speedtext1500 rpm
Duty CycletextStandby, Prime
Engine Modeltext3412C TA, V-12, 4-Stroke Water-Cooled Diesel
Boremeasurement5.4in137.2mm
Strokemeasurement6in152.4mm
Displacementmeasurement1648.86in³27.02l
Compression Ratiotext13:01
AspirationtextTurbocharged, Air to Air Aftercooled
Fuel SystemtextPump and Lines
Governor TypetextADEM™ A5
Length - Maximummeasurement162.4in4125mm
Width - Minimummeasurement75in1906mm
Width - Maximummeasurement78.3in1989mm
Height - Maximummeasurement75in1906mm
Dry Weight - Genset (minimum)measurement12039lb5461kg
Dry Weight - Genset (maximum)measurement13030lb5910kg

Standard Equipment

Air Inlet System

  • Air cleaner, single element canister type with service indicator

Control Panel

  • GCCP Control panel
  • Emergency stop pushbutton
  • Overspeed
  • Text alarm/event descriptions
  • Low coolant temperature
  • Frequency (Hz)
  • Overcurrent (50 / 51)
  • 4 programmable relay outputs (Form A)
  • Volts (L-L & L-N)
  • Programmable protective relaying functions:
  • Warning/shutdownn with common LED indication of shutdowns for:
  • 24 Volt DC operation
  • Over/under voltage (27 / 59)
  • Engine cycle crank
  • Over/under frequency (81 o/u)
  • Remote CAN annunciator
  • Remote Serial annunciator
  • kW (per phase, average & percent)
  • Digital I/O module
  • Failure to start (overcrank)
  • Low oil pressure
  • Low coolant level
  • Run/auto/ stop/control
  • 6 programmable digital inputs
  • Accessory module data link
  • Features include:
  • Compatible with the following optional modules:
  • Serial annunciator module data link
  • kVA (per phase, average & percent)
  • Voltage adjust
  • RPM
  • Generator temperature monitoring module
  • kVAr (per phase, average & percent)
  • 2 Programmable relay outputs (Form C)
  • DC volts
  • Communications
  • Local annunciator
  • Power factor (per phase & average)
  • Speed adjust
  • Emergency stop
  • Reverse power (kW) (32)
  • coolant temperature
  • Digital indication for:
  • Reverse reactive power (kVAr) (32RV)
  • Customer data link (Modbus RTU)
  • kW-hr (total)
  • Amps (per phase & average)
  • High coolant temperature
  • Generator phase sequence
  • Oil pressure (psi, kPa or bar)
  • Operating hours
  • 2 Programmable digital outputs
  • Environmental sealed front face

Cooling System

  • Fan and belt guards
  • Radiator with guard (Sized for 50 degrees C)
  • Coolant drain line with valve, piped to edge of base
  • Coolant level shutdown
  • Caterpillar extended life coolant

Exhaust System

  • Stainless steel exhaust flex with ANSI style outlet flange, gasket, bolts and mating weld flange, shipped loose

Fuel System

  • Primary and Secondary fuel filters
  • Water seperator
  • Flexible fuel lines terminated on base
  • Fuel priming pump

Generator and Attachments

  • 3-phase sensing
  • Busbar termination
  • SR4B self excited
  • 2:1 Volts/Hz
  • Class F temperature rise
  • 12 Leads
  • Class H insulation
  • Reactive droop
  • VR6 voltage regulator

Governing System

  • Cat electronic governor

Lube System

  • Oil drain line with valve, piped to edge of base
  • Oil filter
  • Fumes disposal, piped to front of radiator
  • Lubricating oil

Mounting System

  • Base, formed steel with linear vibration isolators between base and engine-generator

Starting / Charging System

  • Fuel shutoff solenoid
  • 45 amp Charging alternator
  • Battery with rack, cables
  • 24 volt starting motor

Optional Equipment

Air Inlet System

  • Dual element air cleaners
  • Heavy duty air cleaners
  • Open element air cleaners

Circuit breakers

  • 1250, 1600 Amp, 3 pole, IEC 100% rated, 24 volt DC shunt trip
  • 1600 Amp, 3 pole, Non-UL, 100% rated, 24 volt DC shunt trip

Control Panel

  • Ground fault relay
  • Vandal proof panel door
  • First local annunicators
  • Common alarm/shutdown relay
  • Remote custom annunicator
  • GCCP Control panel
  • Generator running VFC
  • GCCP Control panel
  • Local discrete I/O package
  • Generator temperature monitoring package

Cooling System

  • Radiator duct flange
  • Jacket water heaters

European Certifications

  • Eurasian Conformity (EAC) mark

Exhaust System

  • Manifold and turbocharger guards
  • Through wall installation kit
  • Elbow kit
  • Mufflers

Generator and Attachments

  • Permanent magnet excitation (PMG)
  • Space heater
  • Digital voltage regulator
  • Oversize and premium generators

Lube System

  • Manual sump pump

Mounting System

  • Fuel tank base (1200 ltr)

Special Tests / Reports

  • PGS Test report @ 0.8 power factor
  • PGS Test report @ 1.0 power factor

Starting / Charging

  • Battery disconnect switch
  • Heavy duty starting system
  • Battery chargers
  • Oversize batteries

Governing System

  • Electronic load share

Attachments