3516B DGB™ (60 Hz)

3516B Generator Set

The 3516B DGB (Dynamic Gas Blending) generator sets are made to match your continuous and prime applications. Producing reliable power from 1640 to 1825 ekW at 60 Hz, each generator set has been designed to meet ISO 8528-5 transient response requirements and accepts 100 % rated load in one step. Our 3516B DGB generator sets have been developed for low fuel consumption.

Product Images

Product Videos

Virtual Product Tour (VPT)

Specifications

NameTypeValueUnit Value (Imperial)Unit NameUnit Value (Metric)Unit Name (Metric)
Prime Power Ratingtext1825 ekW
Continuous Ratingtext1640 ekW
Emissions/Fuel StrategytextLow Fuel Consumption

View All Specifications (25)

Documents & Spec Sheets

Electric Power Ratings Guide

Download

3516B DGB, 60 Hz, 1875 ekW Prime, 1640 ekW Cont., Low Fuel Consumption Spec Sheet

Download

Features & Benefits

Cat Generator Set Package
  • Cat generator set packages have been fully prototype tested
  • Accepts 100% block load in one step and meets NFPA 110 loading requirements
  • Conform to ISO 8528-5 steady state and transient response requirements
Cat Diesel Engine
  • Reliable, rugged, durable design
  • Field-proven in thousands of applications worldwide
  • Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight
SR5 Alternator
  • Superior motor starting capability minimizes need for oversizing alternator
  • Designed to match performance and output characteristics of Cat diesel engines
  • Robust Class H insulation
Cat ECS Control Panel
  • User-friendly interface and navigation
  • Scalable system to meet a wide range of installation requirement
  • Expansion modules and site-specific programming for specific customer requirements
Cooling System
  • Designed to operate in standard ambient temperatures up to 50°C (122°F)
  • Contact your Cat Dealer for specific ambient and altitude capabilities
One Safe Source
  • Components used in the generator set are selected at the design stage to provide optimum package performance
  • The generator set is fully assembled at a Caterpillar facility following our quality guidelines
  • Each generator set package is tested before leaving the Caterpillar facility
  • Cat product support, including dealer service, parts and warranty covers the entire Cat power system
Worldwide Product Support
  • Cat dealers have over 1,800 dealer branch stores operating in 200 countries
  • Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements

Complete Specifications

Generator Set Specifications

NameTypeValueUnit Value (Imperial)Unit NameUnit Value (Metric)Unit Name (Metric)
Prime Power Ratingtext1825 ekW
Continuous Ratingtext1640 ekW
Emissions/Fuel StrategytextLow Fuel Consumption
Voltagetext380 to 13800 Volts
Frequencytext60 Hz
Speedtext1800 rpm
Duty CycletextPrime, Continuous
Maximum Ratingtext1825 ekW
Minimum Ratingtext1640 ekW
Engine Modeltext3516B TA, V-16, 4-Stroke Water-Cooled Diesel
Boremeasurement6.69in170mm
Strokemeasurement7.48in190mm
Displacementmeasurement4210.64in69l
Compression Ratiotext14.0:1
AspirationtextTA
Fuel SystemtextElectronic unit injection
Governor TypetextAdem™4
Length - Minimummeasurement264.3in6714mm
Length - Maximummeasurement264.3in6714mm
Width - Minimummeasurement90.1in2288mm
Width - Maximummeasurement90.1in2288mm
Height - Minimummeasurement94.1in2391mm
Height - Maximummeasurement94.1in2391mm
Dry Weight - Genset (minimum)measurement33300lb15135kg
Dry Weight - Genset (maximum)measurement33300lb15135kg

Standard Equipment

Air Inlet System

  • Air cleaner, single element canister type

Cooling

  • Package mounted radiator

Exhaust

  • Exhaust flange outlet

Fuel

  • Primary fuel filter with integral water separator
  • Secondary fuel filters

Power Termination

  • Busbar

Control System

  • Generator set packages include Caterpillars voltage regulator
  • 4 Programmable relay outputs (Form A)
  • Overcurrent (50/51)
  • 6 Customer programmable digital inputs
  • Controls:
  • Low coolant temperature
  • Auto/start/stop control
  • Low coolant level
  • Customer data link (Modbus RTU)
  • PLC functionality
  • kVA (per phase, average & percent)
  • Reverse power (kW) (32)
  • Alarm acknowledge
  • kW (per phase, average & percent)
  • kW-hr (total)
  • Lamp test
  • RPM
  • Volts (L-L & L-N), frequency (Hz)
  • Generator phase sequence
  • Operating hours
  • kVAr-hr (total)
  • True RMS AC metering, 3-phase, +/-2% accuracy
  • Over/under frequency (81 o/u)
  • Accessory module data link
  • Number of I/O varies on options selected
  • High coolant temperature
  • Overspeed
  • 1 Programmable digital outputs
  • Regulator (IVR) - IVR includes reactive droop capability, 3-phase voltage sensing, KVAR/PF modes, RFI suppression, min/max exciter
  • DC volts
  • Reverse reactive power (kVAr) (32RV)
  • Amps (per phase & average)
  • Oil pressure (psi, kPa or bar)
  • Coolant temperature
  • Failure to start (overcrank)
  • 3 Analog inputs
  • Power factor (per phase & average)
  • EMCP 4.3
  • kVAr (per phase, average & percent)
  • Cat connect
  • Engine cool-down timer
  • 1 Programmable relay outputs (Form C)
  • Environmental sealed front face
  • Warning/shutdown with common LED indication of shutdowns for:
  • 24 Volt DC operation
  • Over/under voltage (27/59)
  • Emergency stop pushbutton
  • Limiter and exciter diode monitor
  • Generator mounted - rear facing
  • Digital indication for:
  • Text alarm/event descriptions
  • Customizable screens
  • Load histogram feature
  • Emergency stop
  • Serial annunciator module data link
  • Programmable protective relaying functions:
  • Low oil pressure
  • Communications:
  • Speed adjust
  • Engine cycle crank

Control Panel

  • Cat ECS Genset controller

Cooling System

  • Package mounted radiator

Exhaust System

  • Dry exhaust manifold
  • Flanged faced outlet(s)

Fuel System

  • Fuel cooler; not included with packages without radiator
  • Flexible fuel lines - shipped loose
  • Secondary fuel filters
  • Fuel priming pump

General

  • SAE standard rotation
  • Flywheel and Flywheel housing-SAE No. 00
  • Paint - Caterpillar yellow except rails and radiators gloss black
  • RH service

Generators and Attachments

  • Matched to the performance and output characteristics of Cat engines
  • Random wound
  • IP23 Protection
  • Anti-condensation space heater
  • 3 Phase brushless, Salient pole
  • HV:
  • Class H insulation, Class F temperature rise at 40C ambient (105C prime / 130C standby)
  • LV
  • NEMA Class H insulation system, Class H temperature rise at 40C ambient (125C prime / 150C standby) - 60 Hz models: NEMA standard hole pattern
  • 6 Lead
  • Form wound
  • Busbar connections, right side extension box, bottom cable entry - 60 Hz models: NEMA standard hole pattern
  • Winding temperature detectors
  • MV:
  • NEMA Class H insulation system, Class H temperature rise at 40C ambient (125C prime / 150C standby)

Governing System

  • ADEM A3

Lube System

  • Oil drain lines and valve
  • Lubricating oil
  • Integral lube Oil cooler
  • Oil filter, filler and dipstick
  • Fumes disposal
  • Gear type lube oil pump

Mounting System

  • Rails - Engine/generator/radiator mounting.
  • Rubber anti-vibration mounts - shipped loose
  • Anti-vibration mounts (shipped loose)

Starting System

  • Battery disconnect switch
  • 24 Volt electric starting motor
  • 45 Amp Charging alternator
  • Battery and battery rack w/cables

Optional Equipment

Exhaust

  • Exhaust mufflers

Air Inlet System

  • Standard ambient radiators
  • Dual element air cleaner
  • Standard ambient ATAAC radiators
  • Single element filter
  • Optional radiator arrangements

Generator

  • Anti-condensation heater
  • Permanent magnet excitation (PMG)
  • Oversize and premium generators
  • Internal excitation (IE)

Control Panels

  • EMCP 4.4
  • Load share module
  • Digital I/O module
  • Generator main terminal box
  • Remote monitoring software
  • Vandal proof panel cover
  • Generator temperature monitoring & protection
  • Empty upper box
  • Cable Shroud
  • Annunciator - local
  • Digital I/O module
  • Annunciator - remote
  • Side extension box

Cooling System

  • Coolant
  • Water level switch gauges

Crankcase Systems

  • No explosion relief valves
  • Explosion relief valves
  • Crankcase ventilation systems
  • Crankcase protection groups:

Mounting

  • Rubber anti-vibration mounts
  • IBC isolators

Exhaust System

  • Flange and exhaust expanders
  • Flexible fittings
  • Tier 4 lean emissions moDual
  • Flanges
  • Elean emission parts
  • Tier 4 dosing cabinet
  • Exhaust offset
  • Mufflers
  • Tier 4 clean emission MOD kits
  • Y Adapters
  • Elbows>

Starting/Charging

  • Oversize batteries
  • Charging alternator
  • Heavy duty starting system
  • Jacket water heater
  • Battery chargers

General

  • CSA Certification
  • EEC Declaration of Conformity
  • Automatic transfer switches (ATS)
  • UL 2200 package
  • Integral & sub-base UL listed dual wall fuel tanks
  • EU Certificate of Conformance (CE)
  • Integral & sub-base fuel tanks
  • Seismic Certification per applicable building codes: IBC 2000, IBC 2003, IBC 2006, IBC 2009, CBC 2007
  • Enclosures: Sound attenuated, weather protective
  • The following options are based on regional and product configuration:

Extended Service Coverage

  • Platinum, Silver and Gold coverage

Fuel System

  • Primary fuel filter
  • Fuel priming pumps (Tier 4)
  • Gas fuel filter

Generators and Attachments

  • Generator conversions
  • Hi voltage optional attachments
  • 2700 Frame - 6300, 6600, 6900 Volts, 3 Phase 1800 RPM, FW, PM, No. of leads = 6, Pitch = .6667
  • 1600 Frame - 380, 440, 480, 600 Volts, 3 Phase 1800 RPM, RW, PM, No. of leads = 6, Pitch = .6667
  • Generators high voltage
  • Differential current transformers
  • 1600 Frame - 380, 416, 440, 480, 600, 2400, 4160 Volts, 3 Phase 1800 RPM ,FW, PM, No. of leads = 6, Pitch = .6667
  • 1600 Frame - 380, 440, 480, 600 Volts, 3 Phase 1800 RPM, RW, IE, No. of leads = 6, Pitch = .6667
  • Alternator air cleaner
  • 1800 Frame
  • Space heater kit
  • 3000 Frame - 12470, 13200, 13800 Volts, 3 Phase 1800 RPM, FW, PM, No. of leads = 6, Pitch = .6667

Instrumentation

  • Pyrometer and termocouples

Lube System

  • Oil level regulator
  • Prelube pump groups
  • Lube oil in standard sump

Mounting System

  • IBC vibration isolators
  • Puck style low efficiency isolators
  • Spring type vibration isolators

Power Connections

  • Center post busbars
  • Cable entry - rear
  • Rear power connections
  • Cable entry - right side
  • Cable entry - left side
  • Grounding groups
  • Neutral ground connections
  • Right side power connections
  • left side power connections

Power Termination

  • Circuit breakers - LV Packages
  • 2000, 2500, 3200 Amp, 4 Pole, IEC rated Circuit breakers
  • Circuit breakers, IEC compliant
  • Circuit breakers, UL listed
  • 1600, 2000, 2500, 3000 and 4000 Amp, 3 Pole, UL-100% rated Circuit breakers
  • 2000, 2500, 3200 Amp, 3 Pole, IEC rated Circuit breakers

Special Tests / Reports

  • Generator set report
  • PGS Test report @ 0.8 power factor
  • Fuel consumption test
  • Torsional vibration analysis
  • Seismic Certifications
  • PGS Test report @ 1.0 power factor
  • Standard engine test
  • OSPD Certification

Starting / Charging

  • 10, 20, 35 Amp Battery chargers
  • Engine barring device
  • Batteries, racks and cables
  • Jacket water heaters
  • Air starting motors with control and silencer
  • Electric starting motors
  • Starter cover
  • 50 Amp NFPA battery charger
  • Air pressure regulator

Attachments