C1.1 Generator Set
Producing reliable power from 6.8 to 9.5 kVA at 50 Hz, our C1.1 diesel generator sets designed to ISO 8528-5 transient response requirements. All C1.1 generator sets are R96/EUIIIa equivalent emissions compliant.
Product Images
Product Videos
Virtual Product Tour (VPT)
360° Exterior View (HTML)
360° Exterior View (HTML)
Specifications
| Name | Type | Value | Unit Value (Imperial) | Unit Name | Unit Value (Metric) | Unit Name (Metric) |
|---|---|---|---|---|---|---|
| Maximum Rating | text | 9.5 kVA | ||||
| Standby Rating | text | 7.5/9.5 kVA | ||||
| Minimum Rating | text | 6.8 kVA |
Documents & Spec Sheets
Electric Power Ratings Guide
DownloadDE7.5E3S 50 Hz 7.5 kVA, 60 Hz 8.8 kVA, M Frame, EU IIIA Compliant Emissions Spec Sheet
DownloadDE9.5E3 50 Hz 9.5 kVA, 60 Hz 11.0 kVA, M Frame, EU IIIA Emissions Compliant Spec Sheet
DownloadDE9.5E3 50 Hz 9.5 kVA, 60 Hz 11.0 kVA, M Frame, EU IIIA (EUR-1) Compliant Emissions Spec Sheet
DownloadDE7.5E3S 50 Hz 7.5 kVA, 60 Hz 8.8 kVA, LC Frame, EU IIIA Emissions Compliant Spec Sheet
DownloadDE9.5E3 50 Hz 9.5 kVA, 60 Hz 11.0 kVA, LC Frame, EU IIIA Emissions Compliant Spec Sheet
DownloadDE9.5E3 50 Hz 9.5 kVA, 60 Hz 11.0 kVA, LC Frame, EU IIIA (EUR-1) Emissions Compliant Spec Sheet
DownloadC1C2 Diesel Generator Sets, 6.8 - 22 kVA, 50/60 Hz, Spec Sheet
DownloadC1C2 Diesel Generator Sets, 6.8 - 22 kVA, 50/60 Hz, Spec Sheet
DownloadFeatures & Benefits
Cat Generator Set Package
- Cat generator set packages have been fully prototype tested
- Accepts 100% block load in one step and meetsNFPA 110 loading requirements
- Conform to ISO 8528-5 steady state and transient response requirements
Cat Diesel Engine
- Reliable, rugged, durable design
- Field-proven in thousands of applications worldwide
- Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight
M-Frame Alternator
- Superior motor starting capability minimizes need for oversizing alternator
- Designed to match performance and output characteristics of Cat diesel engines
- Robust Class H insulation
GCCP 1.3 Control Panel
- User-friendly interface and navigation
- Scalable system to meet a wide range of installation requirement
- Expansion modules and site-specific programming for specific customer requirements
- Image may not be a representative of actual product
Cooling System
- Designed to operate in standard ambient temperatures up to 55°C (131°F)
- Contact your Cat Dealer for specific ambient and altitude capabilities
Certifications
Cat Dealers provide extensive post sale support including maintenance and repair agreements. Cat dealers have over 1,800 dealer branch stores operating in 200 countries. The Cat® SOSSM program cost effectively detects internal engine component condition, even the presence of unwanted fluids and combustion by-products.
One Safe Source
- Components used in the generator set are selected based on seamless design integration to provide the optimum performance
- The generator set is fully assembled at a Caterpillar facility following our quality guidelines
- Each generator set package is tested before leaving the Caterpillar facility
- Cat product support, including dealer service, parts and warranty covers the entire Cat power system
World Wide Product Support
- Cat dealers have over 1,800 dealer branch stores operating in 200 countries
- Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements
Complete Specifications
Generator Set Specifications
| Name | Type | Value | Unit Value (Imperial) | Unit Name | Unit Value (Metric) | Unit Name (Metric) |
|---|---|---|---|---|---|---|
| Maximum Rating | text | 9.5 kVA | ||||
| Standby Rating | text | 7.5/9.5 kVA | ||||
| Minimum Rating | text | 6.8 kVA | ||||
| Prime Power Rating | text | 6.8/8.5 kVA | ||||
| Emissions/Fuel Strategy | text | EU Stage IIIA | ||||
| Voltage | text | 110 to 415 Volts | ||||
| Frequency | text | 50 Hz | ||||
| Speed | text | 1500 rpm | ||||
| Duty Cycle | text | Standby, Prime | ||||
| Engine Model | text | C1.1, In-line 4 4-cycle diesel | ||||
| Bore | measurement | 3 | in | 77 | mm | |
| Stroke | measurement | 3.2 | in | 81 | mm | |
| Displacement | measurement | 69 | in³ | 1.1 | l | |
| Compression Ratio | text | 23.0:1 | ||||
| Aspiration | text | Naturally Aspirated | ||||
| Fuel System | text | Indirect Injection | ||||
| Governor Type | text | Mechanical | ||||
| Length - Maximum | measurement | 55.1 | in | 1400 | mm | |
| Width - Maximum | measurement | 24.4 | in | 620 | mm | |
| Height - Maximum | measurement | 39.2 | in | 996 | mm |
Standard Equipment
Air Inlet System
- Air cleaner; light duty with disposable element
Control Panel
- GCCP1.3 Control panel
Cooling System
- Caterpillar extended life coolant
- Coolant drain line with valve
- Fan drive, battery charging alternator drive
- Radiator and cooling fan with guards
Exhaust System
- Stub pipe, gaskets, raincap & SAE exhaust flange for customer use - shipped loose
Fuel System
- Base, formed steel with single wall integral 8-hour fuel tank
- Standard open set fuel tank/base supplied
General
- Engine and alternator pre-paint, Caterpillar yellow
Generators and Generator Attachments
- 12 Leads
- Circuit breaker, IEC, 3 pole, mounted in tower panel
- IP23 Protection
- Segregated low voltage (AC/DC) wiring panel
- Tower panel, IP22, bottom cable entry
- Voltage regulator (single phase sensing)
Governing System
- Mechanical governing system
Lube System
- Lubricating oil
- Oil drain line with valve
Mounting System
- Anti-vibration mounts
- Captive linear vibration isolators between base and engine-generator
- Includes lifting provisions and termination points for coolant
- Skidbase as standard
Starting / Charging System
- 12 Volt battery with rack and cables
Optional Equipment
Alternator Options
- Coastal insulation protection
Certificates
- European upgrade to STD set for CE certificate
- Global certification for CIS
Circuit breakers
- 4 Pole Circuit breaker
- Padlockable breaker device
Control Panel
- Battery charger
- Emergency stop with key
Cooling System
- Coolant heater
Enclosures
- Single point lift for enclosure
- Sound attenuated enclosure (GALV)
Fuel System
- Low fuel level alarm
General
- Packing case - canopied set
- Packing case - compact set
- Radiator stone guard
Mounting Options
- Battery removal
- Industrial silencer removal
- Silencer installation kit
Special Test and Inspection
- PGS Test report @ 1.0 power factor