C175-20 (50 Hz)

C175-20

Producing reliable power from 3150 - 4000 kVA in 50 Hz, our C175-20 diesel generator sets are made to meet your mission critical, continuous, standby and prime applications. We've designed each to ISO 8528-5 transient response requirements and to accept 100% rated load in one step. The generator set is optimized for low fuel consumption or low emissions.

Product Images

Product Videos

Virtual Product Tour (VPT)

Specifications

NameTypeValueUnit Value (Imperial)Unit NameUnit Value (Metric)Unit Name (Metric)
Standby Ratingtext4000(no fan)/3900/3350(no fan) kVA
Prime Power Ratingtext3600(no fan)/3500 kVA
Emissions/Fuel StrategytextLow Fuel, Low Emissions

View All Specifications (25)

Documents & Spec Sheets

Electric Power Rating Guide

Download

C175 Generator Sets Product Brochure

Download

C175-20, 50 Hz, 3900 kVA Standby/MC, 3500 kVA Prime, 3150 kVA Cont., Low Fuel Consumption / Low Emissions (with fan) Spec Sheet

Download

C175-20, 50 Hz, 4000 kVA Standby/MC, 3600 kVA Prime, 3250 kVA Cont., Low Fuel Consumption / Low Emissions (without fan) Spec Sheet

Download

C175-20, 50 Hz, 3350 kVA Standby/MC, Low Emissions (without fan) Spec Sheet

Download

C175-20, 50 Hz, 3500 kVA, Prime-DCP, Low Fuel Consumption (with fan) Spec Sheet

Download

C175-20, 50 Hz, 3600 kVA, Prime-DCP, Low Fuel Consumption (without fan) Spec Sheet

Download

Features & Benefits

Cat Generator Set Package
  • Cat generator set packages have been fully prototype tested
  • Accepts 100% block load in one step and meets NFPA 110 loading requirements
  • Conform to ISO 8528-5 steady state and transient response requirements
Cat Diesel Engine
  • Reliable, rugged, durable design
  • Field-proven in thousands of applications worldwide
  • Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight
SR5 Alternator
  • Superior motor starting capability minimizes need for oversizing alternator
  • Designed to match performance and output characteristics of Cat diesel engines
  • Robust Class H insulation
Cat ECS Control Panel
  • User-friendly interface and navigation
  • Scalable system to meet a wide range of installation requirement
  • Expansion modules and site-specific programming for specific customer requirements
Cooling System
  • Designed to operate in standard ambient temperatures up to 50°C (122°F)
  • Contact your Cat Dealer for specific ambient and altitude capabilities
Certifications
  • EU Declaration of Conformity
  • EU Declaration of Incorporation
  • Eurasian Conformity (EAC)
  • IBC seismic certification
One Safe Source
  • Components used in the generator set are selected at the design stage to provide optimum package performance
  • The generator set is fully assembled at a Caterpillar facility following our quality guidelines
  • Each generator set package is tested before leaving the Caterpillar facility
  • Cat product support, including dealer service, parts and warranty covers the entire Cat power system

Complete Specifications

Generator Set Specifications

NameTypeValueUnit Value (Imperial)Unit NameUnit Value (Metric)Unit Name (Metric)
Standby Ratingtext4000(no fan)/3900/3350(no fan) kVA
Prime Power Ratingtext3600(no fan)/3500 kVA
Emissions/Fuel StrategytextLow Fuel, Low Emissions
Voltagetext400 to 11000 Volts
Frequencytext50 Hz
Speedtext1500 RPM
Duty CycletextStandby, Mission Critical, Prime, Continuous
Maximum Ratingtext4000 kVA
Minimum Ratingtext3150 kVA
Engine ModeltextC175-20 SCAC, V-20, 4-Stroke Water-Cooled Diesel
Boremeasurement6.89in175mm
Strokemeasurement8.66in220mm
Displacementmeasurement6456.31in³105.8l
Compression Ratiotext15.3:1
AspirationtextTurbo Aftercooled
Fuel SystemtextCommon Rail
Governor TypetextADEM� A4
Length - Minimummeasurement264.2in6711mm
Length - Maximummeasurement330.8in8402mm
Width - Minimummeasurement85.1in2162mm
Width - Maximummeasurement127.8in3247mm
Height - Minimummeasurement87.6in2224mm
Height - Maximummeasurement150.7in3827mm
Dry Weight - Genset (minimum)measurement55100lb25000kg
Dry Weight - Genset (maximum)measurement66200lb30000kg

Standard Equipment

Air Inlet

  • 4 x Single element canister air cleaners with service indicator(s).

Control Panel

  • Engine cycle crank
  • Oil pressure (psi, kPa or bar)
  • Digital Indicators
  • Coolant temperature
  • Environmental sealed front face
  • Frequency (Hz)
  • True RMS AC metering, 3-phase, +/-2% accuracy
  • Text alarm/event descriptions
  • Low coolant level
  • Volts (L-L & L-N)
  • Auto/start/stop control
  • Warning/shutdown Indicators:
  • Emergency stop pushbutton
  • Engine cool-down timer
  • DC volts
  • High coolant temperature
  • Operating hours
  • Low oil pressure
  • Cat ECS 100
  • Amps (per phase & average)
  • 4 Programmable relay Inputs
  • Alarm acknowledge
  • 4 Programmable relay output
  • Failure to start (overcrank)
  • Overspeed
  • Lamp test
  • 24 Volt DC operation
  • Wall mounted controls
  • RPM

Cooling System

  • SCAC cooling
  • Coolant sensors
  • JW Inlet: 6" ANSI / JW Outlet: 5" Cat Flange
  • AC Inlet: 6" ANSI / AC Outlet: 3-1/2" ANSI

Exhaust

  • Dry exhaust manifold
  • Bolted flange (ANSI 6" & DIN 150) with bellow for each turbo (Qty 4). 50 Hz

Fuel

  • Filters x 3
  • Secondary/tertiary fuel filters
  • 4 Micron spin on type
  • 10 Micron spin on type
  • Engine mounted filters x 3
  • Primary fuel filter water/fuel water separator

Generators and Attachments

  • Salient pole
  • RFI suppression
  • Anti-condensation space heater
  • IEC platinum Stator RTDs
  • Form wound
  • NEMA Class H insulation
  • Voltage regulator
  • Reactive droop capability
  • Min/max Exciter limiter
  • 3 Phase voltage sensing
  • Exciter diode monitor
  • 6 Leads
  • 3 Phase brushless
  • Right side extension box, bottom cable entry
  • Permanent magnet excitation (PMG)
  • Class H temperature rise at 40C ambient

Governing System

  • ADEM A4
  • Redundant shutdown (Overspeed protection through a duplicate speed sensing system)

Lube System

  • Oil drain lines and valve
  • Gear type lube oil pump
  • Oil filter, filler and dipstick
  • Integral lube Oil cooler
  • Lubricating oil
  • Fumes disposal

Mounting Systems

  • Rails - Engine/Generator
  • Rubber anti-vibration mounts - shipped loose

Starting / Charging System

  • Batteries and battery rack w/cables
  • Dual 24 volt electric starting motors
  • Battery disconnect switch

General

  • SAE standard rotation
  • Right hand servicing
  • Paint - Caterpillar yellow with high gloss black rails

Optional Equipment

Air Inlet Systems

  • Single element air cleaner

Control Panels

  • EMCP 4.4
  • Controller and MV and HV power connection locations
  • Load share module
  • Controller voltage and current sensing groups
  • Speed adjust
  • Annunciator modules
  • Customer interface options
  • Generator temperature monitoring
  • E-Stop
  • Interconnect harness
  • Generator harness
  • Modbus monitoring of packages
  • Vandal proof panel door

Cooling System

  • Package mounted radiators
  • Remote radiators
  • Fuel cooler

Crankcase Systems

  • Explosive relief valves
  • Crankcase ventilation system

Exhaust System

  • Front housing - Standby or mission critical
  • Front housing - Prime or continuous
  • Exhaust collectors/manifold
  • Mufflers (15, 25 and 34 dBA)

Fuel System

  • Primary fuel filter

Generators and Attachments

  • Medium voltage - 3000 Frames - 50 Hz, 3 phase, 1500 rpm, FW, PM, No of leads=6, Pitch 0.6667
  • Thermostat for space heater
  • Generator air cleaner
  • Differential current transformers - (5, 9 and 15 kV Class)

Instrumentation

  • Pyrometer and thermocouples

Lube System

  • Lube oil heater
  • Lube oil heater with Crankcase explosion relief valves
  • Drain group oil pans
  • Lubricating oil
  • Electric prelube pumps
  • Oil filters

Mounting System

  • Rubber anti-vibration mounts
  • Spring type linear vibration isolators
  • IBC vibration isolators - Shipped loose

Special Tests / Reports

  • Generator test report
  • PGS Test report @ 1.0 power factor
  • PGS Test report @ 0.8 power factor
  • Standard genset TVA (Torsional Vibration Analysis) report
  • Custom generator TVA report
  • Special test charge - Engine only
  • Genset fuel consumption test
  • Standard engine test charge

Starting / Charging System

  • 24 Volt electric starting motor
  • Air starting motor
  • Air pressure regulator
  • Starter location covers
  • 24 Volt battery set - Dry
  • 20, 35 and 50 Amp Battery chargers
  • Charging alternators - Dry
  • Jacket water heaters

General

  • Special paint - 3500, Colors (other than Caterpillar yellow or high performance paints)
  • US aid emblem
  • Service tools
  • Engine barring group
  • Manual
  • Engine barring air powered
  • control GP - air powered bar group

Attachments