C18 (60 Hz)

C18 Generator Set

The C18 diesel generator sets developed for mission critical, standby and prime applications. Producing reliable power from 455 to 600 ekW at 60 Hz, meeting ISO 8528-5 transient response requirements and built to accept 100 % rated load in one step. Our C18 generator sets range from low fuel consumption systems to EPA Stationary Emergency (Tier 2) certified Emissions / Fuel Strategy.

Product Images

Product Videos

Virtual Product Tour (VPT)

Specifications

NameTypeValueUnit Value (Imperial)Unit NameUnit Value (Metric)Unit Name (Metric)
Maximum Ratingtext600 ekW
Standby Ratingtext550/600/650/715/750 ekW
Minimum Ratingtext455 ekW

View All Specifications (20)

Documents & Spec Sheets

Electric Power Ratings Guide

Download

C18, DE650SE0, 60 Hz, 650 ekW Standby, 600 ekW Prime, Low BSFC Spec Sheet

Download

C18, DE715SE0, 60 Hz, 716 ekW Standby, 650 ekW Prime, Low BSFC Spec Sheet

Download

C18, DE750SE0, 60 Hz, 750 ekW Standby, 680 ekW Prime, Low BSFC Spec Sheet

Download

C18, DE550SE0, 60 Hz, 550 ekW Standby, 500 ekW Prime, Non-Certified Emissions Spec Sheet

Download

C18 for industrial applications

Download

Features & Benefits

Cat Generator Set Package
  • Cat generator set packages have been fully prototype tested
  • Accepts 100% block load in one step and meets NFPA 110 loading requirements
  • Conform to ISO 8528-5 steady state and transient response requirements
Cat Diesel Engine
  • Reliable, rugged, durable design
  • Field-proven in thousands of applications worldwide
  • Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight
SR5 Alternator

A-Frame Alternator

  • Superior motor starting capability minimizes need for oversizing alternator
  • Designed to match performance and output characteristics of Cat diesel engines
  • Robust Class H insulation
GCCP 1.2 and GCCP 1.5 ControlPanel

GCCP Control Panel

  • GCCP 1.2 and GCCP 1.5 Control panel
  • User-friendly interface and navigation
  • Scalable system to meet a wide range of installation requirement
  • Expansion modules and site-specific programming for specific customer requirements
EMCP Control Panel
GCCP Control Panel
Cooling System
  • Designed to operate in standard ambient temperatures up to 55°C (131°F)
  • Contact your Cat Dealer for specific ambient and altitude capabilities
Certifications
  • UL2200 Listed; CSA 22.2; Certification of Compliance – IBC Seismic; Dual IBC & HCAI
One Safe Source
  • Components used in the generator set are selected based on seamless design integration to provide the optimum performance
  • The generator set is fully assembled at a Caterpillar facility following our quality guidelines
  • Each generator set package is tested before leaving the Caterpillar facility
  • Cat product support, including dealer service, parts and warranty covers the entire Cat power system
Worldwide Product Support
  • Cat dealers have over 1,800 dealer branch stores operating in 200 countries
  • Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements

Complete Specifications

Generator Set Specifications

NameTypeValueUnit Value (Imperial)Unit NameUnit Value (Metric)Unit Name (Metric)
Maximum Ratingtext600 ekW
Standby Ratingtext550/600/650/715/750 ekW
Minimum Ratingtext455 ekW
Prime Power Ratingtext500/545/600/650/680 ekW
Emissions/Fuel StrategytextLow BSFC
Voltagetext208 to 600 Volts
Frequencytext60 Hz
Speedtext1800 rpm
Duty CycletextStandby, Prime
Engine ModeltextC18 ATAAC, I-6, 4-Stroke Water-Cooled Diesel
Boremeasurement5.71in145mm
Strokemeasurement7.2in183mm
Displacementmeasurement1106.4in³18.1l
Compression Ratiotext14.5:1
AspirationtextAir to Air Aftercooled
Fuel SystemtextElectronic unit injection
Governor TypetextAdem™A4
Length - Maximummeasurement218.5in5550mm
Width - Maximummeasurement80.9in2056mm
Height - Maximummeasurement107.8in2737mm

Standard Equipment

Air Inlet

  • Air cleaner

Air Inlet System

  • Light duty air cleaner
  • Turbocharger
  • Aftercooler core

Governing System

  • Cat electronic governor (ADEM A4)

Control System

  • GCCP 1.2

Cooling

  • Radiator and cooling fan with guard
  • Fan drive, battery charging alternator drive
  • Coolant drain line with valve
  • Caterpillar extended life coolant
  • Package mounted radiator

Exhaust

  • Exhaust flange outlet

Exhaust System

  • Stainless steel exhaust flex gaskets, raincap and SAE exhaust flange for customer use - shipped loose

Fuel

  • Fuel priming pump
  • Secondary fuel filters
  • Primary fuel filter with integral water separator

Fuel System

  • Standard 8 hour open set fuel tank

Generator and Attachments

  • Matched to the performance and output characteristics of Cat engines
  • Integrated voltage regulator (IVR)
  • Segregated low voltage (AC/DC) wiring panel
  • A Frame generator - IP21 protection
  • Integrated voltage regulator (IVR)
  • Mandatory option circuit breaker, IEC, 3 pole, mounted in power centre
  • Power center, IP22

Generator

  • IP23 Protection
  • Matched to the performance and output characteristics of Cat engines
  • Load adjustment module provides engine relief upon load impact and improves load acceptance and recovery time

Power Termination

  • Busbar

Control Panel

  • GCCP 1.2 and GCCP 1.5

Lube System

  • Lubricating oil
  • Oil drain valves

Mounting

  • Rubber vibration isolators

Mounting System

  • Captive linear vibration isolators between base and engine-generator. includes lifting provisions and termination points for coolant and lube oil drain lines

Starting/Charging

  • 24 Volt battery with rack and cables
  • 24 volt starting motor
  • Batteries

General

  • Engine and alternator pre-paint, Caterpillar yellow
  • Paint - Caterpillar yellow except rails and radiators gloss black

Optional Equipment

Air Inlet System

  • Dual element air cleaner
  • Single element air cleaner

Exhaust

  • Industrial, residential, critical mufflers

Circuit breakers

  • 3 Pole (IEC-100% rated) Circuit breakers - Motorised
  • Power terminal strip
  • 3 Pole (IEC-100% rated) Circuit breakers - Package mounted
  • Shunt trip for IEC breaker
  • Padlockable circuit breaker device
  • Circuit breaker (IEC) Auxiliary contacts
  • 4 Pole (IEC-100% rated) Circuit breakers - Package mounted
  • 4 Pole (IEC-100% rated) Circuit breakers - Motorised

Generator

  • Anti-condensation heater
  • Oversize and premium generators
  • Excitation: [ ] Permanent magnet excitation (PMG) Excited (PM) [ ] Internally Excited (IE)

Power Termination

  • Circuit breakers, UL listed
  • Circuit breakers, IEC compliant

Control Panel

  • GCCP 1.2, GCCP 1.5

Control Panels

  • Load share module
  • Local & remote annunciator modules
  • Remote monitoring software
  • Digital I/O module

Control System

  • Protective devices: Earth fault relay - earth leageage Ground fault relay - Overload shutdown via breaker - Low fuel level alarm - Low fuel level shutdown - High fuel level alarm - Fuel level sensor
  • Local alarm modules
  • Local alarm horn
  • Oil temperature displays
  • GCCP 1.5
  • Volt free contact
  • Remote annunciator module

Starting/Charging

  • Heavy duty starting system
  • Battery chargers
  • Jacket water heater
  • Charging alternator
  • Oversize batteries

Cooling System

  • Low coolant temperature alarm
  • Radiator duct flange

Enclosures

  • Sound attenuated enclosures

Exhaust System

  • Engine mounted muffler
  • 8 and 10 inch GP flanges
  • 10, 25 and 35 end in / end out mufflers
  • Manifold and turbocharger guards
  • 8 and 10 inch elbow kits

Fuel System

  • Manual fuel transfer pump
  • Optional BS799 Compliant Integral - Dual wall fuel tank base
  • Fuel transfer system

General

  • Single or dual wall integral fuel tanks
  • Automatic transfer switches (ATS)
  • UL 2200 package
  • The following options are based on regional and product configuration:
  • Single or dual wall sub-base fuel tanks
  • EEC Declaration of Conformity
  • Sound attenuated, weather protective or high ambient weather protective enclosure
  • Enclosures: Sound attenuated, weather protective
  • EU Certificate of Conformance (CE)
  • CSA Certification
  • Seismic Certification per applicable building codes: IBC 2000, IBC 2003, IBC 2006, IBC 2009, CBC 2007
  • Integral & sub-base UL listed dual wall fuel tanks
  • Narrow, wide or skid base

Generator and Attachments

  • Ingress protection
  • Permanent magnet excitation (PMG)
  • A Frame CIP generator
  • LC frame generator
  • LC frame oversize generators
  • A Frame oversize generator
  • LC frame CIP generator
  • Space heaters

Lube System

  • Manual sump pump

Starting and Charging

  • Jacket water heaters
  • 5 Amp Battery charger
  • Battery disconnect switch

Attachments