C18 (60 Hz) Tier 4

C18 Generator Set

The C18 diesel generator sets have been developed for your mission critical, standby and prime applications. Producing reliable power from 455 to 500 ekW at 60 Hz, meeting ISO 8528-5 transient response requirements and built to accept 100 % rated load in one step. The engines are certified to the US EPA Tier 4 Final emissions levels.

Product Images

Product Videos

Virtual Product Tour (VPT)

Specifications

NameTypeValueUnit Value (Imperial)Unit NameUnit Value (Metric)Unit Name (Metric)
Standby Ratingtext500 ekW
Maximum Ratingtext500 ekW
Prime Power Ratingtext455 ekW

View All Specifications (17)

Documents & Spec Sheets

Electric Power Rating Guide

Download

C18, 60 Hz, 500 ekW Standby, US EPA Tier 4 Final Nonroad Emission Standard Spec Sheet

Download

C18, 60 Hz, 455 ekW Prime, US EPA Tier 4 Final Nonroad Emission Standard Spec Sheet

Download

C18, 60 Hz, 500 ekW Standby, 455 ekW Prime, US EPA Tier 4 Final Non-Road Emission Spec Sheet

Download

GCCP 1.2 Control Panel Data Sheet

Download

GCCP 1.5 Control Panel Data Sheet

Download

Features & Benefits

Cat Generator Set Package
  • Cat generator set packages have been fully prototype tested
  • Accepts 100% block load in one step and meets NFPA 110 loading requirements
  • Conform to ISO 8528-5 steady state and transient response requirements
Cat Diesel Engine
  • Reliable, rugged, durable design
  • Field-proven in thousands of applications worldwide
  • Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight
A-Frame Alternator
  • Superior motor starting capability minimizes need for oversizing alternator
  • Designed to match performance and output characteristics of Cat diesel engines
  • Robust Class H insulation
GCCP 1.2 Control Panel
  • User-friendly interface and navigation
  • Scalable system to meet a wide range of installation requirement
  • Expansion modules and site-specific programming for specific customer requirements
Cooling System
  • Designed to operate in standard ambient temperatures up to 55°C (131°F)
  • Contact your Cat Dealer for specific ambient and altitude capabilities
Certifications
  • UL2200 Listed; CSA 22.2; Certification of Compliance – IBC Seismic; Dual IBC & HCAI
One Safe Source
  • Components used in the generator set are selected based on seamless design integration to provide the optimum performance
  • The generator set is fully assembled at a Caterpillar facility following our quality guidelines
  • Each generator set package is tested before leaving the Caterpillar facility
  • Cat product support, including dealer service, parts and warranty covers the entire Cat power system
World Wide Product Support
  • Cat dealers have over 1,800 dealer branch stores operating in 200 countries
  • Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements
Cat Clean Emissions Module (CEM)
  • The Tier 4 Final engine has been optimized to work with the Cat CEM.
  • The CEM is a reliable, compact, and lightweight system that gives maximum installation flexibility.
  • It features a diesel oxidation catalyst for particulate matter (PM) and hydrocarbon (HC) control.
  • Selective catalytic reduction (SCR) reduces NOx output and provides integrated sound attenuation.
  • The CEM is controlled by a separate dosing module that has been integrated into the standard generator set controls for complete monitoring, protection and closed loop NOx control.
  • For more information on the CEM, refer to cut sheet LEHE0359.
UL 2200 / CSA - Optional
  • UL 2200 listed packages
  • CSA Certified
  • Certain restrictions may apply.
  • Consult with your Cat® Dealer.

Complete Specifications

Generator Set Specifications

NameTypeValueUnit Value (Imperial)Unit NameUnit Value (Metric)Unit Name (Metric)
Standby Ratingtext500 ekW
Maximum Ratingtext500 ekW
Prime Power Ratingtext455 ekW
Minimum Ratingtext455 ekW
Emissions/Fuel StrategytextU.S. EPA Tier 4 Certified
Voltagetext480 Volts
Frequencytext60 Hz
Speedtext1800 rpm
Duty CycletextStandby, Prime
Engine ModeltextC18 ATAAC, I-6, 4-Stroke Water-Cooled Diesel
Boremeasurement1455.7in145mm
Strokemeasurement7.2in183mm
Displacementmeasurement1106.4in³18.1l
Compression Ratiotext14.5:1
AspirationtextAir to Air Aftercooled
Fuel SystemtextElectronic unit injection
Governor TypetextAdem™A4

Standard Equipment

Air Inlet

  • Air cleaner

Exhaust System

  • Exhaust manifold - dry

Cooling

  • Package mounted radiator

Fuel System

  • Fuel cooler
  • Engine fuel transfer pump
  • Primary fuel filter w/integral water separator and secondary filter
  • Fuel priming pump
  • Flexible fuel lines

Exhaust

  • Exhaust flange outlet

Fuel

  • Primary fuel filter with integral water separator
  • Fuel priming pump
  • Secondary fuel filters

Generator

  • Matched to the performance and output characteristics of Cat engines
  • IP23 Protection
  • Load adjustment module provides engine relief upon load impact and improves load acceptance and recovery time

Power Termination

  • Busbar

Lube System

  • Oil filter and dipstick
  • Lubricating oil
  • Oil drain lines with valve; piped to edge of base
  • Fumes disposal, piped to front of radiator
  • Oil cooler

Control Panel

  • GCCP Genset Controller

Mounting

  • Rubber vibration isolators

Protection System

  • Safety shutoffs for: Higher water temperature - Overspeed - Low oil pressure

Cooling System

  • Thermostats and housing, full open temperature 92 deg C (198 deg F)
  • Coolant level sensor
  • Coolant level sight gauge
  • Fan and belt guards
  • Jacket water pump, gear driven, centrifugal
  • Coolant drain line with valve; terminated on edge of base
  • Caterpillar extended life coolant

Starting/Charging

  • 24V, 45 Amp Charging alternator
  • 24 Volt electric starting motor
  • 24 volt starting motor
  • Batteries

General

  • Paint - Caterpillar yellow except rails and radiators gloss black
  • Paint, Caterpillar yellow
  • Operation and maintenance manual pack and OMM storage compartment
  • Parts book
  • Vibration damper

Control System

  • Local annunciator
  • Programmable Input / Output: 2 programmable digital inputs - 2 programmable relay outputs (Form A) - 2 programmable relay outputs (Form C)
  • Suitable for use as service equipment label
  • Separation plate
  • Control panel mounting location
  • Breaker box mounting location
  • Optional external analog input
  • Remote annunciators
  • GCCP 1.2
  • Communications: Customer data link (RS485 Modbus RTu) - Serial annunciator module data link for local and remote annunciator IVR - Integrated Voltage Regulation (Digital) - EM10 Excitation Module
  • Controls include: Run/auto/ stop/control - Speed adjust - Voltage adjust - Engine cycle crank - Emergency stop pushbutton
  • Digital indication for: rpm - DC volts - operating hours - Oil pressure (psi, kPa or bar) - Coolant temperature (C or F) - Volts (L-L & L-N), frequency (Hz) - Amps (per phase & average) - Power factor (per phase & average) - kW (per phase & average) - kVA (per phase & average) - kVAr (per phase and average) - kW-hr (total) - kVAr-hr (total)
  • Programmable protective relaying functions: Generator phase sequence - Over/under voltage (27/59) - Over/under frequency (81 o/u) - Overcurrent (50/51)
  • Warning/shutdown with common LED indication of shutdowns for: Low oil pressure - high coolant temperature - Overspeed - Emergency stop - Failure to start (overcrank) - Low coolant temperature - Low coolant level
  • Control panel options: Dust proof control panel - volt free contact - Device server - Ground fault relay

Governing System

  • Cat electronic governor (ADEM A4)

Generator and Attachments

  • Segregated low voltage (AC/DC) wiring panel
  • Brushless, self-excited 2/3 pitch, random wound.
  • Insulation Class H and temperature rise
  • AREP generator
  • CIP - generators
  • IP23 Protection
  • Power center, IP22 bottom cable entry

Air Inlet System

  • Single element air filter
  • Air cleaner - Heavy duty
  • Air cleaner - Single element

Extended Service Coverage

  • Silver, Gold and Platinum coverage

Circuit breakers

  • 3 Pole 100% rated

Optional Equipment

Control System

  • Optional external analog input
  • Control panel mounting
  • Ground fault relay
  • Dust proof control panel
  • Breaker box mounting location
  • Volt free contact
  • Device server
  • Separation plate
  • Remote annunciators
  • GCCP 1.5
  • Local annunciator
  • Remote E-stop button

Exhaust

  • Industrial, residential, critical mufflers

Generator

  • Anti-condensation heater
  • Excitation: [ ] Permanent magnet excitation (PMG) Excited (PM) [ ] Internally Excited (IE)
  • Oversize and premium generators

Power Termination

  • Circuit breakers, UL listed

Generators and Attachments

  • AREP generator
  • CIP generators
  • Space heater
  • Generator mounting and duct plate

Air Inlet System

  • Single element air filter
  • Dual element air cleaner

Certifications

  • Certificate of Compliance
  • IBC Certification wind load

Circuit breakers

  • Motorized single circuit breaker
  • Neutral bars
  • Power cables
  • Dual breakers first circuit breaker (CB2) LS/I package mounted
  • Current transformers
  • Package mounted single circuit breakers
  • Dual breakers first circuit breaker (CB1) LS/I package mounted
  • Auxiliary contacts

Cooling System

  • Aftertreatment guard
  • Standard radiator

Enclosures

  • Sound attenuated enclosures

Exhaust System

  • Flange kits
  • Exhaust flexible fittings

Fuel System

  • 660 gallon base tank

Generator Attachments

  • Permanent magnet excitation (PMG) generator

Mounting System

  • Standard base wide
  • 5 Gallon spill containment
  • Optional CB shroud
  • Overfill prevention valve
  • Locking fuel fill

Starting / Charging System

  • Battery disconnect switch
  • Jacket water heater
  • Shore power control group
  • 10 Amp dual Battery charger

TESTS

  • PGS Test report @ 0.8 power factor
  • 4 Hour factory test (un-witnessed)
  • PGS Test report @ 1.0 power factor
  • Generator test report