C18 (50 Hz)

C18 Generator Set

The C18 diesel generator sets have been developed for your mission critical, standby and prime applications. Producing reliable power from 550 to 715 kVA at 50 Hz, meeting ISO 8528-5 transient response requirements and built to accept 100 % rated load in one step. Our C18 generator sets range from Low Fuel Consumption, Low Emissions and China Nonroad III Emission Standards Emissions / Fuel Strategy.

Product Images

Product Videos

Virtual Product Tour (VPT)

Specifications

NameTypeValueUnit Value (Imperial)Unit NameUnit Value (Metric)Unit Name (Metric)
Maximum Ratingtext715 kVA
Standby Ratingtext605/660/715/780/850 kVA
Minimum Ratingtext550 kVA

View All Specifications (20)

Documents & Spec Sheets

Electric Power Ratings Guide

Download

C18, DE605E0, 50 Hz, 605 kVA Standby, 550 kVA Prime, Non-Certified Emissions Spec Sheet

Download

C18, DE600C3, 50 Hz, 600 kVA Prime, China Non-Road-III Spec Sheet

Download

DE715E0, 50 Hz, 715 kVA Standby, 650 kVA Prime, Non-Certified Emissions Spec Sheet

Download

C18, DE660E0, 50 Hz, 660 kVA Standby, 600 kVA Prime, Non-Certified Emissions Spec Sheet

Download

C18, DE780E0, 50 Hz, 780 kVA Standby, 706 kVA Prime, Low BSFC Spec Sheet

Download

C18, DE850E0, 50 Hz, 850 kVA Standby, 770 kVA Prime, Low BSFC Spec Sheet

Download

Features & Benefits

Cat Generator Set Package
  • Cat generator set packages have been fully prototype tested
  • Accepts 100% block load in one step and meets NFPA 110 loading requirements
  • Conform to ISO 8528-5 steady state and transient response requirements
Cat Diesel Engine
  • Reliable, rugged, durable design
  • Field-proven in thousands of applications worldwide
  • Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight
A-Frame Alternator
  • Superior motor starting capability minimizes need for oversizing alternator
  • Designed to match performance and output characteristics of Cat diesel engines
  • Robust Class H insulation
GCCP1.3 Control Panel
  • User-friendly interface and navigation
  • Scalable system to meet a wide range of installation requirement
  • Expansion modules and site-specific programming for specific customer requirements
Cooling System
  • Designed to operate in standard ambient temperatures up to 55°C (131°F)
  • Contact your Cat Dealer for specific ambient and altitude capabilities
Certifications
One Safe Source
  • Components used in the generator set are selected based on seamless design integration to provide the optimum performance
  • The generator set is fully assembled at a Caterpillar facility following our quality guidelines
  • Each generator set package is tested before leaving the Caterpillar facility
  • Cat product support, including dealer service, parts and warranty covers the entire Cat power system
Worldwide Product Support
  • Cat dealers have over 1,800 dealer branch stores operating in 200 countries
  • Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements

Complete Specifications

Generator Set Specifications

NameTypeValueUnit Value (Imperial)Unit NameUnit Value (Metric)Unit Name (Metric)
Maximum Ratingtext715 kVA
Standby Ratingtext605/660/715/780/850 kVA
Minimum Ratingtext550 kVA
Prime Power Ratingtext550/600/650/706/770/600 kVA
Emissions/Fuel StrategytextChina Non-Road Stage III Certified / Non-Certified Emissions
Voltagetext380 to 415 Volts
Frequencytext50 Hz
Speedtext1500 rpm
Duty CycletextStandby, Prime
Engine ModeltextC18 ATAAC, I-6, 4-Stroke Water-Cooled Diesel
Boremeasurement5.71in145mm
Strokemeasurement7.2in183mm
Displacementmeasurement1106.36in³18.13l
Compression Ratiotext14.5:1
AspirationtextAir to Air Aftercooled
Fuel SystemtextElectronic unit injection
Governor TypetextAdem™A4
Length - Maximummeasurement162.4in4135mm
Width - Maximummeasurement78.3in1989mm
Height - Maximummeasurement75in1906mm

Standard Equipment

Air Inlet System

  • Turbocharger
  • Light duty air cleaner
  • Aftercooler core

Air Inlet

  • Air cleaner

Control System

  • GCCP 1.2

Exhaust

  • Exhaust flange outlet

Cooling

  • Coolant drain line with valve
  • Caterpillar extended life coolant
  • Fan drive, battery charging alternator drive
  • Radiator and cooling fan with guard

Exhaust System

  • Stainless steel exhaust flex gaskets, raincap and SAE exhaust flange for customer use - shipped loose

Fuel

  • Secondary fuel filters
  • Fuel priming pump
  • Primary fuel filter with integral water separator

Fuel System

  • Standard 8 hour open set fuel tank

Generator

  • IP23 Protection
  • Load adjustment module provides engine relief upon load impact and improves load acceptance and recovery time
  • Matched to the performance and output characteristics of Cat engines

Generator and Attachments

  • Segregated low voltage (AC/DC) wiring panel
  • Integrated voltage regulator (IVR)
  • A Frame generator - IP21 protection
  • Integrated voltage regulator (IVR)
  • Mandatory option circuit breaker, IEC, 3 pole, mounted in power centre
  • Power center, IP22
  • Matched to the performance and output characteristics of Cat engines

Power Termination

  • Busbar

Governing System

  • Cat electronic governor (ADEM A4)

Control Panel

  • GCCP Genset Controller

Lube System

  • Lubricating oil
  • Oil drain valves

Mounting

  • Rubber vibration isolators

Mounting System

  • Captive linear vibration isolators between base and engine-generator. includes lifting provisions and termination points for coolant and lube oil drain lines

Starting/Charging

  • 24 Volt battery with rack and cables

General

  • Engine and alternator pre-paint, Caterpillar yellow

Optional Equipment

Exhaust

  • Industrial, residential, critical mufflers

Air Inlet System

  • Dual element air cleaner
  • Single element air cleaner

Circuit breakers

  • 3 Pole (IEC-100% rated) Circuit breakers - Motorised
  • 4 Pole (IEC-100% rated) Circuit breakers - Motorised
  • Circuit breaker (IEC) Auxiliary contacts
  • Padlockable circuit breaker device
  • 3 Pole (IEC-100% rated) Circuit breakers - Package mounted
  • 4 Pole (IEC-100% rated) Circuit breakers - Package mounted
  • Power terminal strip
  • Shunt trip for IEC breaker

Generator

  • Anti-condensation heater
  • Excitation: [ ] Permanent magnet excitation (PMG) Excited (PM) [ ] Internally Excited (IE)
  • Oversize and premium generators

Power Termination

  • Circuit breakers, IEC compliant
  • Circuit breakers, UL listed

Control Panels

  • Local & remote annunciator modules
  • Load share module
  • Remote monitoring software
  • EMCP (4.2) (4.3) (4.4)
  • Digital I/O module

Control System

  • Oil temperature displays
  • GCCP 1.5
  • Volt free contact
  • Protective devices: Earth fault relay - earth leageage Ground fault relay - Overload shutdown via breaker - Low fuel level alarm - Low fuel level shutdown - High fuel level alarm - Fuel level sensor
  • Local alarm modules
  • Remote annunciator module
  • Local alarm horn

Cooling System

  • Low coolant temperature alarm
  • Radiator duct flange

Starting/Charging

  • Oversize batteries
  • Jacket water heater
  • Battery chargers
  • Heavy duty starting system
  • Charging alternator

Enclosures

  • Sound attenuated enclosures

Exhaust System

  • Manifold and turbocharger guards
  • Engine mounted muffler
  • 8 and 10 inch elbow kits
  • 8 and 10 inch GP flanges
  • 10, 25 and 35 end in / end outmufflers

Fuel System

  • Fuel transfer system
  • Optional BS799 Compliant Integral - Dual wall fuel tank base
  • Manual fuel transfer pump

Generator and Attachments

  • LC frame generator
  • Permanent magnet excitation (PMG)
  • LC frame oversize generators
  • Space heaters
  • A Frame oversize generator
  • A Frame CIP generator
  • Ingress protection
  • LC frame CIP generator

General

  • Single or dual wall integral fuel tanks
  • UL 2200 package
  • Enclosures: Sound attenuated, weather protective
  • EU Certificate of Conformance (CE)
  • Integral & sub-base UL listed dual wall fuel tanks
  • Narrow, wide or skid base
  • The following options are based on regional and product configuration:
  • Seismic Certification per applicable building codes: IBC 2000, IBC 2003, IBC 2006, IBC 2009, CBC 2007
  • EEC Declaration of Conformity
  • CSA Certification
  • Sound attenuated, weather protective or high ambient weather protective enclosure
  • Automatic transfer switches (ATS)
  • Single or dual wall sub-base fuel tanks

Lube System

  • Manual sump pump

Starting and Charging

  • Jacket water heaters
  • 5 Amp Battery charger
  • Battery disconnect switch

Attachments