C280-16

C280-16 Generator Set (Medium Speed)

Producing reliable power from 4400 to 4840 ekW at 60 Hz and 5875 to 6500 kVA at 50Hz, our C280-16 diesel generator sets are made to meet your mission critical, continuous, standby and prime applications. We've designed each to ISO 8528-5 transient response requirements and to accept 100% rated load in one step. The generator set can be configured to meet IMO/EPA Tier 2 or EPA Tier 4 Final.

Product Images

Product Videos

Virtual Product Tour (VPT)

Specifications

NameTypeValueUnit Value (Imperial)Unit NameUnit Value (Metric)Unit Name (Metric)
Maximum Ratingtext4840 ekW (60Hz), 6500 kVA (50Hz)
Minimum Ratingtext4400 ekW (60Hz), 5875 kVA (50Hz)
Emissions/Fuel StrategytextEPA Tier 4 Final, IMO Tier 2

View All Specifications (18)

Documents & Spec Sheets

Product Rating Guide

Download

C280-16 Spec Sheet: 60 Hz 4840 ekW, 50Hz 6500 kVA

Download

Features & Benefits

Cat Diesel Engine
  • Reliable, rugged, durable design
  • Field-proven in thousands of applications worldwide
  • Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight
Generator
  • Matched to the performance and output characteristics of Cat engines
  • Industry leading mechanical and electrical design
  • Industry leading motor starting capabilities
  • High Efficiency
Worldwide Product Support
  • Cat dealers provide extensive post-sale support including maintenance and repair agreements.
  • Cat dealers have over 1,800 dealer branch stores operating in 200 countries. The Caterpillar S��?�O��?�S��?��?��? program cost effectively detects internal engine component condition, even the presence of unwanted fluids and combustion by-products
Full Range of Attachments
  • Wide range of bolt-on system expansion attachments, factory designed and tested Flexible packaging options for easy and cost effective installation

Complete Specifications

Generator Set Specifications

NameTypeValueUnit Value (Imperial)Unit NameUnit Value (Metric)Unit Name (Metric)
Maximum Ratingtext4840 ekW (60Hz), 6500 kVA (50Hz)
Minimum Ratingtext4400 ekW (60Hz), 5875 kVA (50Hz)
Emissions/Fuel StrategytextEPA Tier 4 Final, IMO Tier 2
Frequencytext50 / 60 Hz
Speedtext900 / 1000 rpm
Duty CycletextPrime, Continuous
Engine ModeltextC280-16, V-16,4-Stroke Water-Cooled Diesel
Boremeasurement11in280mm
Strokemeasurement11.8in300mm
Displacementmeasurement18032in³296l
Compression Ratiotext13:01
AspirationtextTA
Fuel SystemtextDirect unit injection
Governor TypetextGenerator Set Monitoring System (GMS)
Length - Maximummeasurement404in10261.7mm
Width - Maximummeasurement99.62in2530.3mm
Height - Maximummeasurement156.6in3977.7mm
Dry Weight - Genset (maximum)measurement141840lb64470kg

Standard Equipment

Air Inlet System

Air Inlet System

  • Air inlet shutoff
  • Turbocharger, watercooled, engine oil lubricated
  • Breather, crankcase, top-mounted
  • Aftercooler, fresh water, corrosion resistant coated (air side)
  • Air cleaner

Air Inlet System

Air Inlet System

Air Inlet System

Air Inlet System

Air Inlet System

Air Inlet System

Air Inlet System

Air Inlet System

Air Inlet System

Air Inlet System

Air Inlet System

Air Inlet System

Air Inlet System

Air Inlet System

Air Inlet System

Air Inlet System

Air Inlet System

Air Inlet System

Air Inlet System

Air Inlet System

Air Inlet System

Cooling System

  • Three-bundle oil cooler
  • Jacket water thermostats
  • Front Mounted turbos
  • Engine coolant water drains
  • Water temperature regulator

Exhaust System

  • Dry, gas tight, exhaust manifold
  • 457 mm (18 in) Cat bolt pattern
  • Includes adapter, flexible exhaust fitting

Fuel System

  • Simplex or duplex

Generator System

  • Custom generator per generator data sheet completed by dealer

Governor System

  • UG Actuator

Lube System

  • Wet oil sump. Includes engine-driven main lubrication and oil pumps, oil lines and oil pan
  • Centrifugal oil filters with single shutoff
  • Oil filler and dipstick
  • Service Side Engine mounted on Cylinder Block Inspection Covers
  • Crankcase explosion relief valves
  • Oil pressure regulating valve

Mounting System

  • Damper, torsional vibration
  • Engine and generator mounting

Starting / Charging System

  • Line group for single point custom connection
  • Two Motors, engine mounted at rear, on left side
  • Vane type air starter
  • Air silencer

General:

  • Gear driven pumps: Fuel/oil/jacket water/Aftercooler/Oil cooler water
  • Paint, Caterpillar yellow

Optional Equipment

Air Inlet System

  • Air inlet adapter
  • Vertical support bracket
  • Air cleaner louver assembly
  • Boost control valve
  • Soot filter
  • Heavy duty air cleaner

Cooling System

  • Auxiliary water pump
  • Heat exchanger for single circuit
  • Expansion tank
  • Cooling system aids
  • Heating aids

Exhaust System

  • Flexible exhaust Fittings
  • Weld flange and related hardware

Fuel System

  • Duplex primary fuel strainer
  • Fuel system connections
  • Fuel priming pump

Generator System

  • Winding temperature detectors
  • Anti-condensation space heaters
  • 3 Phase, Six Leads, WYE
  • Class F insulation
  • Busbar connections

Governor System

  • Electronic/actuators
  • EGB actuator
  • Digital programmers
  • Battery backup/power supply
  • 230 UA
  • 723 Plus

Lube System

  • Oil pan drain valve
  • Lube ANSI Adapter (Emergency connection)

Mounting System

  • Spring type vibration isolators
  • Vertically Restrained
  • Non-vertically Restrained
  • Isolator

Starting / Charging System

  • Compressed air flex hose
  • Turbine type air starters
  • Pressure reducing valve
  • Redundant air starters

General:

  • Custom paint colors

Attachments