NameTypeValueUnit Value (Imperial)Unit NameUnit Value (Metric)Unit Name (Metric)
Standby Ratingtext300 ekW
Maximum Ratingtext300 ekW
Minimum Ratingtext300 ekW

View All Specifications (23)

Documents & Spec Sheets

Electric Power Ratings Guide

Download

D300 GC, C9, 60 Hz, 300 ekW Spec Sheet

Download

Cat® GC Generator Set Brochure for North America

Download

D250 -D600 GC Enclosure Brochure

Download

GCCP 1.2 Control Panel Data Sheet

Download

GCCP 1.5 Control Panel Data Sheet

Download

Features & Benefits

Cat Generator Set Package
  • Cat generator set packages have been fully prototype tested
  • Accepts 100% block load in one step and meets NFPA 110 loading requirements
  • Conform to ISO 8528-5 steady state and transient response requirements
Cat Diesel Engine
  • Reliable, rugged, durable design
  • Field-proven in thousands of applications worldwide
  • Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight
M-Frame Alternator
  • Superior motor starting capability minimizes need for oversizing alternator
  • Designed to match performance and output characteristics of Cat diesel engines
  • Robust Class H insulation
GCCP 1.2 Control Panel
  • User-friendly interface and navigation
  • Expansion modules and site-specific programming for specific customer requirements
Cooling System
  • Designed to operate in standard ambient temperatures up to104°F (40°C)
  • Contact your Cat Dealer for specific ambient and altitude capabilities
Certifications
  • UL 2200 Listed
  • ULC Certification Available
One Safe Source
  • Components used in the generator set are selected based on seamless design integration to provide the optimum performance
  • The generator set is fully assembled at a Caterpillar facility following our quality guidelines
  • Each generator set package is tested before leaving the Caterpillar facility
  • Cat product support, including dealer service, parts and warranty covers the entire Cat power system
Worldwide Product Support
  • Cat dealers have over 1,800 dealer branch stores operating in 200 countries
  • Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements

Complete Specifications

Generator Set Specifications

NameTypeValueUnit Value (Imperial)Unit NameUnit Value (Metric)Unit Name (Metric)
Standby Ratingtext300 ekW
Maximum Ratingtext300 ekW
Minimum Ratingtext300 ekW
Frequencytext60 Hz
Emissions/Fuel StrategytextU.S. EPA Tier 3 Certified
Voltagetext208 to 600 Volts
Speedtext1800 rpm
Duty CycletextStandby
Engine ModeltextCat® C9 In-line 6, 4-cycle diesel
Boremeasurement4.4in112mm
Strokemeasurement5.9in149mm
Displacementmeasurement538in³8.8l
Compression Ratiotext16.3:1
AspirationtextTurbocharged Air-to-Air Aftercooled
Fuel SystemtextHEUI
Governor TypetextAdem™A4
Length - Maximummeasurement155.5in3950mm
Width - Minimummeasurement56.3in1430mm
Width - Maximummeasurement56.7in1440mm
Height - Minimummeasurement67.2in1706mm
Height - Maximummeasurement86.7in2202mm
Dry Weight - Genset (minimum)measurement5518.2lb2503kg
Dry Weight - Genset (maximum)measurement6929.1lb3143kg

Standard Equipment

Air Inlet System

  • Aftercooler core
  • Turbocharger
  • Air cleaner - Non canister, disposable

Control Panel

  • GCCP 1.2

Cooling System

  • Jacket water pump, gear driven, centrifugal
  • Thermostats and housing
  • Coolant drain valve
  • Radiator sight gauge
  • Blower fan and fan drive with guards
  • Radiator, package mounted

Exhaust System

  • Exhaust manifold - dry

Fuel System

  • Integral tank base, 24 hours, UL142
  • Fuel priming pump
  • Engine fuel transfer pump
  • Primary fuel filter w/integral water separator and secondary filter, spin on

Generator Set

  • Complete system designed & built at ISO 9001:2000 certified facilities
  • All protective devices and control functions simulated and checked
  • Factory tested to design specifications at full load conditions

Generators and Generator Attachments

  • IP23 Protection
  • 12 Leads
  • Insulation system, Class H
  • Standard winding protection for non-harsh environments with relative humidity ? 95%
  • Voltage regulator (single phase sensing)
  • Easy access to AVR and terminals
  • Terminal box, IP22 RHS facing, bottom cable entry
  • Brushless, self-excited 2/3 pitch (600V uses Internal excitation (IE))

Governing System

  • Cat electronic governor (ADEM A4)

Lube System

  • Shallow oil pan
  • Oil cooler
  • Fumes disposal to front of radiator
  • Oil drain with valve
  • Oil filler and dipstick
  • Oil filter, spin on
  • Lubricating oil, CK-4 (10W-30)

Mounting System

  • Captive linear vibration isolators between base and engine-generator
  • Includes lifting provisions and termination points for coolant and lube oil drain lines

Protection

  • Safety shutoff - High water temperature
  • Safety shutoff - Low oil pressure
  • Safety shutoff - Overspeed

Starting/Charging System

  • 24-volt electric starting motor
  • 24V, 45 Amp Charging alternator

General

  • Lifting eyes
  • Vibration damper
  • Parts book

Optional Equipment

Air Inlet System

  • Air cleaner (Non canister disposable)

Bases, Mounting & Fuel Tanks

  • Integral tank base, 24 hours, UL142
  • Audio & visual fuel alarm (@90% fuel level)
  • Wide Base - Skid
  • Fuel tank pill pipe & lockable cap

Circuit breaker

  • 1200A LSI
  • 800A LS/I
  • Auxiliary contacts
  • 600A LS/I
  • 1200A LS/I
  • 400A LS/I
  • 800A LSI
  • 400A LSI
  • 600A LSI

Control System

  • Audible alarm Gp
  • 16 -light NFPA 99/110 Annunciator
  • Twist release, Red button emergency stop
  • Ground fault relay
  • 100A Load center
  • Product link remote monitoring hardware
  • 20A GFCI (Ground Fault Circuit Interrupter)
  • Volt free contacts

Enclosures

  • Sound attenuated Level 2 enclosure (White)
  • AC & DC Source lights
  • E-Stop

Exhaust System

  • 6" Muffler - 25 dBA attenuation
  • Manifold and turbocharger guards
  • Flexible exhaust connection

Generator

  • Space heater
  • Permanent magnet excitation (PMG) generator

Starting System

  • Battery charger (UL Certified)
  • Jacket water heater
  • Standard battery set: 1000 CCA, 90 amp/hr.

General

  • CSA Certification
  • Extended Service Coverage
  • UL2200 Certification
  • Generator test report